Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Comput Biol Med ; 169: 107781, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38103481

RESUMO

This article presents an overview of existing approaches to perform vectorcardiographic (VCG) diagnostics of ischemic heart disease (IHD). Individual methodologies are divided into categories to create a comprehensive and clear overview of electrical cardiac activity measurement, signal pre-processing, features extraction and classification procedures. An emphasis is placed on methods describing the electrical heart space (EHS) by several features extraction techniques based on spatiotemporal characteristics or signal modelling and signal transformations. Performance of individual methodologies are compared depending on classification of extent of ischemia, acute forms - myocardial infarction (MI) and myocardial scars localization. Based on a comparison of imaging methods, the advantages of VCG over the standard 12-leads ECG such as providing a 3D orthogonal leads imaging, better performance, and appropriate computer processing are highlighted. The issues of electrical cardiac activity measurements on body surface, the lack of VKG databases supported by a more accurate imaging method, possibility of comparison with the physiology of individual cases are outlined as potential reserves for future research.


Assuntos
Infarto do Miocárdio , Vetorcardiografia , Humanos , Vetorcardiografia/métodos , Coração/fisiologia , Miocárdio , Processamento de Sinais Assistido por Computador , Eletrocardiografia/métodos
4.
Acta Chir Belg ; 123(1): 90-93, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34006182

RESUMO

BACKGROUND: Solitary fibrous tumour of the liver is a rare mesenchymal tumour, occurring usually in women and with various symptomatology. The symptoms mostly result from pressure of the tumour mass on surrounding organs. Due to unknown biological behaviour and gradual increase of tumour volume, surgical resection is mostly the preferred treatment option. CASE: A 75-year-old woman with a history of endometrial cancer, presenting with an incidental finding of a liver mass, initially considered of infectious origin (either echinococcosis or cysticercosis). Further diagnostics did not clarify the aetiology, a surgical revision was rejected at the time. The subsequent follow-up was interrupted by the development of symptoms of gastrointestinal and renal obstruction, which led to a complete surgical removal of the tumour, sized 30 × 25 × 20 cm. A histopathological examination showed a CD34 and STAT6 positivity, leading to a diagnosis of a giant solitary fibrous tumour of the liver. The patient recovered well, without any signs of recurrence. CONCLUSION: The solitary fibrous tumour of the liver is a rare, often incidental finding. It is considered benign, but malignant growth was also reported. A gradual growth mostly results in pressure on other organs. A surgical resection is the treatment of choice. Transarterial embolization is another treatment possibility. Due to indeterminate malignant potential a regular follow-up is necessary, including tumour markers and imaging methods.


Assuntos
Tumores Fibrosos Solitários , Humanos , Feminino , Idoso , Tumores Fibrosos Solitários/diagnóstico , Tumores Fibrosos Solitários/cirurgia , Tumores Fibrosos Solitários/patologia , Fator de Transcrição STAT6 , Biomarcadores Tumorais , Fígado/patologia
5.
Front Physiol ; 14: 1260074, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38239883

RESUMO

Introduction: This study proposes an algorithm for preprocessing VCG records to obtain a representative QRS loop. Methods: The proposed algorithm uses the following methods: Digital filtering to remove noise from the signal, wavelet-based detection of ECG fiducial points and isoelectric PQ intervals, spatial alignment of QRS loops, QRS time synchronization using root mean square error minimization and ectopic QRS elimination. The representative QRS loop is calculated as the average of all QRS loops in the VCG record. The algorithm is evaluated on 161 VCG records from a database of 58 healthy control subjects, 69 patients with myocardial infarction, and 34 patients with bundle branch block. The morphologic intra-individual beat-to-beat variability rate is calculated for each VCG record. Results and Discussion: The maximum relative deviation is 12.2% for healthy control subjects, 19.3% for patients with myocardial infarction, and 17.2% for patients with bundle branch block. The performance of the algorithm is assessed by measuring the morphologic variability before and after QRS time synchronization and ectopic QRS elimination. The variability is reduced by a factor of 0.36 for healthy control subjects, 0.38 for patients with myocardial infarction, and 0.41 for patients with bundle branch block. The proposed algorithm can be used to generate a representative QRS loop for each VCG record. This representative QRS loop can be used to visualize, compare, and further process VCG records for automatic VCG record classification.

6.
Front Physiol ; 13: 941827, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36338495

RESUMO

This paper deals with a wavelet-based algorithm for automatic detection of isoelectric coordinates of individual QRS loops of VCG record. Fiducial time instants of QRS peak, QRS onset, QRS end, and isoelectric PQ interval are evaluated on three VCG leads ( X , Y , Z ) together with global QRS boundaries of a record to spatiotemporal QRS loops alignment. The algorithm was developed and optimized on 161 VCG records of PTB diagnostic database of healthy control subjects (HC), patients with myocardial infarction (MI) and patients with bundle branch block (BBB) and validated on CSE multilead measurement database of 124 records of the same diagnostic groups. The QRS peak was evaluated correctly for all of 1,467 beats. QRS onset, QRS end were detected with standard deviation of 5,5 ms and 7,8 ms respectively from the referee annotation. The isoelectric 20 ms length PQ interval window was detected correctly between the P end and QRS onset for all the cases. The proposed algorithm complies the ( 2 σ C S E ) limits for the QRS onset and QRS end detection and provides comparable or better results to other well-known algorithms. The algorithm evaluates well a wide QRS based on automated wavelet scale switching. The designed multi-lead approach QRS loop detector accomplishes diagnostic VCG processing, aligned QRS loops imaging and it is suitable for beat-to-beat variability assessment and further automatic VCG classification.

7.
Cureus ; 14(11): e31406, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36382323

RESUMO

Endofibrosis is a rare disease that predominantly affects athletes and is caused by a gradual occlusion of the (usually iliac) artery due to a thickening of the intima. From our experience, we report in this article two cases with the entity of endofibrosis in females around 30 years old. The first case presented with acute limb ischemia, and the second one was with pain in the leg during exercise. In addition, both cases are professional cyclists. They were eventually diagnosed with endofibrosis and underwent surgical procedures. They are now pursuing their professional career successfully. Last but not least, endofibrosis might be classified as an occupational disease, particularly, in the case of professional athletes or cyclists.

14.
Artigo em Inglês | MEDLINE | ID: mdl-33885048

RESUMO

BACKGROUND: Non-alcoholic fatty liver disease (NAFLD), often associated with obesity and metabolic syndrome, manifests itself as steatosis, hepatic fibrosis, cirrhosis, or even end-stage liver disease. NAFLD causes inflammation, insulin resistance and cardiovascular complications. The current study aimed to evaluate the beneficial effects of bariatric surgery on biochemical parameters of hepatic functions in obese patients by comparing them before and one-year after the surgery. METHODS: A total of 72 morbidly obese patients underwent bariatric surgery between 2016 and 2018. The incidence of diabetes mellitus in this group was 29%, median body weight was 124.5 kg (109.0-140.0) and mean body mass index (BMI) was 44.38 ± 6.770 kg/m2. The used surgical procedures included gastric bypass, sleeve gastrectomy, laparoscopic gastric plication, and single anastomosis duodeno-ileal bypass-sleeve gastrectomy. Biochemical parameters including ALT/AST ratio (AAR), NAFLD fibrosis score (NFS), hepatic fibrosis index (FIB-4) and Fatty Liver Index (FLI) were evaluated in all patients at the time of surgery and one year after the intervention. RESULTS: Significant improvement after the intervention was observed in 64 patients. A significant reduction in body weight (P<0.0001), waist circumference (P<0.0001), and body mass index (P<0.0001) were observed. NAFLD liver fibrosis index changed significantly (P<0.0001), suggesting a trend of improvement from advanced fibrosis towards stages 0-2. The FIB-4 fibrosis index indicated significant improvement (P=0.0136). Besides, a significant decline in hepatic steatosis (P<0.0001) was observed after bariatric surgery as compared to the pre-surgery fatty liver conditions. CONCLUSION: Among the strategies to overcome NAFLD-associated impediments, bariatric surgery can be considered effective in reducing obesity and metabolic co-morbidities. TRIAL REGISTRATION: ClinicalTrials.gov (NCT04569396).


Assuntos
Cirurgia Bariátrica , Hepatopatia Gordurosa não Alcoólica , Obesidade Mórbida , Cirurgia Bariátrica/efeitos adversos , Fibrose , Seguimentos , Humanos , Fígado , Cirrose Hepática/complicações , Hepatopatia Gordurosa não Alcoólica/etiologia , Hepatopatia Gordurosa não Alcoólica/cirurgia , Obesidade Mórbida/complicações , Obesidade Mórbida/patologia , Obesidade Mórbida/cirurgia , Estudos Prospectivos
15.
Wideochir Inne Tech Maloinwazyjne ; 15(3): 469-477, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32904607

RESUMO

INTRODUCTION: Bariatric surgery has a significant impact on dietary intake, weight loss, patient's metabolism and also on defaecation stereotypes. AIM: To investigate changes in bowel habits of morbidly obese patients after laparoscopic sleeve gastrectomy (LSG). MATERIAL AND METHODS: This was a prospective clinical cohort study conducted to assess changes in bowel habits after LSG in a single institution. RESULTS: In total, 124 patients were enrolled in the study (age 47.1 ±11.2 years, body mass index (BMI) 44.3 ±6.8 kg/m2). The mean weight loss 6 months after LSG was 29.1 ±11.1 kg; percentage excess weight loss was 56.2 ±20.4%. Before surgery, 35.5% of patients had constipation and 6.5% of patients had faecal incontinence (FI). No correlation was found between rising level of BMI and constipation or incontinence prevalence/severity. Data analysis has not confirmed increased prevalence/severity of postoperative constipation or incontinence 6 months after LSG. Out of the group of patients with preoperative constipation, clinically relevant improvement was noted in 45.5% of patients after the surgery. Among patients without constipation before surgery, impairment was noted in 21.2% of patients. Out of the group of patients with preoperative incontinence, improvement was found in 37.5% of patients; none of these patients reported clinically relevant impairment of incontinence symptoms. CONCLUSIONS: The present study has not revealed increased prevalence/severity of postoperative constipation or anal incontinence 6 months after LSG. Our findings suggest that weight loss in patients after LSG might be associated with an improvement of constipation symptoms of individual patients.

16.
Asian J Surg ; 43(9): 902-906, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31911035

RESUMO

BACKGROUND: To evaluate the safety, feasibility and outcomes of patients treated for colorectal liver metastases (CLM) with an innovative combined approach - hepatic resection and Stereotactic body radiotherapy (SBRT) using CyberKnife® system. METHODS: This was a retrospective cohort study conducted in a single institution. Patients with CLM and no evidence of extrahepatic disease were included during a 6-year study period. RESULTS: In total, 19 patients with 63 liver lesions underwent liver resection combined with SBRT of unresectable lesions. Major hepatectomy was performed in 42.1% patients; postoperative complications were noted in 31.6% patients. 27 unresectable lesions were treated by SBRT with a total dose of 50-60 Gy in five fractions. The median follow-up of study patients was 29.7 ± 20.58 months. Local control of CLM at 1 and 2 years was achieved in 89.5% of patients. Out-of-field hepatic recurrence was diagnosed in 63.1% patients. The 1-year disease-free survival (DFS) was 52.6%; 2-year DFS was 31.6%. The overall actuarial survival rates at 1 and 2 years were 88.2% and 50.4%. CONCLUSION: Liver resection combined with SBRT presents a promising therapeutic option for patients with CLM which traditionally are unresectable. The additional use of SBRT allows for the effective clearance of the disease for thoroughly selected patients.


Assuntos
Carcinoma/secundário , Carcinoma/cirurgia , Neoplasias Colorretais/patologia , Hepatectomia/métodos , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Radiocirurgia/métodos , Idoso , Carcinoma/mortalidade , Estudos de Coortes , Estudos de Viabilidade , Feminino , Humanos , Neoplasias Hepáticas/mortalidade , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
17.
Sensors (Basel) ; 20(1)2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31906383

RESUMO

This paper presents a newly-designed and realized Invasive Blood Pressure (IBP) device for the simulation on patient's monitors. This device shows improvements and presents extended features with respect to a first prototype presented by the authors and similar systems available in the state-of-the-art. A peculiarity of the presented device is that all implemented features can be customized from the developer and from the point of view of the end user. The realized device has been tested, and its performances in terms of accuracy and of the back-loop measurement of the output for the blood pressure regulation utilization have been described. In particular, an accuracy of ±1 mmHg at 25 °C, on a range from -30 to 300 mmHg, was evaluated under different test conditions. The designed device is an ideal tool for testing IBP modules, for zero setting, and for calibrations. The implemented extended features, like the generation of custom waveforms and the Universal Serial Bus (USB) connectivity, allow use of this device in a wide range of applications, from research to equipment maintenance in clinical environments to educational purposes. Moreover, the presented device represents an innovation, both in terms of technology and methodologies: It allows quick and efficient tests to verify the proper functioning of IBP module of patients' monitors. With this innovative device, tests can be performed directly in the field and faster procedures can be implemented by the clinical maintenance personnel. This device is an open source project and all materials, hardware, and software are fully available for interested developers or researchers.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Pressão Sanguínea/fisiologia , Monitorização Fisiológica/instrumentação , Determinação da Pressão Arterial/métodos , Calibragem , Desenho de Equipamento , Humanos , Monitorização Fisiológica/métodos , Software
18.
Oncol Lett ; 15(5): 6309-6321, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29616108

RESUMO

This present study investigated the impact of the application of stem cells to liver regeneration following the first stage of associating liver partition and portal vein ligation for staged hepatectomy (ALPPS). The experiment was conducted on a pig model (n=6, 3 that did not receive application of stem cells, 3 that received application stem cells). Collected samples of liver (day 0 and 9 following surgery) were subjected to complete transcriptome sequencing. In total, 39 differentially expressed genes were found in the group without the application of the stem cells (genes of unwanted processes such as fibrosis and inflammation). In the group that did receive application of stem cells, no significantly differentially expressed genes were found, indicating a properly regenerated liver remnant. The present study therefore demonstrated, to the best of our knowledge for the first time, the positive effect of stem cells application in the liver regeneration process during ALPPS procedure in the pig model.

19.
ANZ J Surg ; 88(6): E512-E516, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28922706

RESUMO

BACKGROUND: Low anterior resection syndrome (LARS) covers disordered bowel function after rectal resection, leading to deterioration in patients' quality of life. The aim of this study was to evaluate anorectal function after laparoscopic low anterior resection (LAR) by means of standardized instruments. METHODS: This was a prospective clinical cohort study conducted in a single institution to assess functional outcome of patients 1 year after laparoscopic LAR by means of LARS score and high-resolution anorectal manometry. RESULTS: In total, 65 patients were enrolled in the study. Mean tumour height was 9.4 ± 1.8 cm; total mesorectal excision during laparoscopic LAR with low end-to-end colorectal anastomosis was performed in all patients. One year after the surgery, minor LARS was detected in 33.9% of patients, major LARS in 36.9% of patients. Anorectal manometry revealed decreased resting pressure and normal squeeze pressure of the anal sphincters in the majority of our patients. Rectal compliance and rectal volume tolerability (first sensation, urge to defaecate and discomfort volume) were significantly reduced. The statistical testing of the correlation between LARS and manometry parameters showed that with increasing seriousness of LARS, values of some parameters (resting pressure, first sensation, urge to defaecate, discomfort volume and rectal compliance) were reduced. CONCLUSION: This study indicates that the majority of patients after laparoscopic LAR experience symptoms of minor or major LARS. These patients have decreased resting anal sphincter pressures, decreased rectal volume tolerability and decreased rectal compliance.


Assuntos
Manometria/métodos , Protectomia/métodos , Proctoscopia/métodos , Qualidade de Vida , Neoplasias Retais/patologia , Neoplasias Retais/cirurgia , Idoso , Canal Anal/cirurgia , Anastomose Cirúrgica/métodos , Estudos de Coortes , Defecação/fisiologia , Incontinência Fecal/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/psicologia , Protectomia/efeitos adversos , Estudos Prospectivos , Recuperação de Função Fisiológica , Neoplasias Retais/mortalidade , Medição de Risco , Resultado do Tratamento
20.
Exp Clin Transplant ; 15(1): 21-26, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28122484

RESUMO

Many investigations on surgical methods and medical treatment are currently done on pigs. This is possible because the pig is sufficiently close genetically to humans. In recent years, progress in liver surgery has opened new possibilities in surgical treatment of liver diseases. Because the methods are relatively novel, various improvements are still needed, and it is thus helpful to conduct experimental surgeries on pig livers. We reviewed the literature to compare the anatomic and functional features of pig and human livers, information that will be of great importance for improving surgical techniques. During the literature review, we used various sources, such as PubMed, Scopus, and veterinary journals. Our results were summarized in diagrams to facilitate understanding of the vascular structure and biliary systems. We conclude that, although the shapes of the human and pig livers are quite different, the pig liver is divided into the same number of segments as the human liver, which also shows a common structure of the vascular system. Thus, with the anatomic and structural features of the pig liver taken into account, this animal model can be used in experimental hepatic surgery.


Assuntos
Ductos Biliares/anatomia & histologia , Artéria Hepática/anatomia & histologia , Veias Hepáticas/anatomia & histologia , Fígado/irrigação sanguínea , Fígado/cirurgia , Veia Porta/anatomia & histologia , Fatores Etários , Animais , Ductos Biliares/cirurgia , Ablação por Cateter/métodos , Embolização Terapêutica/métodos , Hepatectomia/métodos , Artéria Hepática/cirurgia , Veias Hepáticas/cirurgia , Humanos , Transplante de Fígado/métodos , Modelos Animais , Tamanho do Órgão , Veia Porta/cirurgia , Especificidade da Espécie , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...